BQVBP - METALCLAD CERAMALLOY CP PLUS BASE

  • MSDS: BQVBP
  • Manufacturer: PALMER INTERNATIONAL INC
  • Product Name: METALCLAD CERAMALLOY CP PLUS BASE
  • National Stock Number: 8040-00N037686
Product Identification

Product ID:METALCLAD CERAMALLOY CP PLUS BASE
MSDS Date:12/01/1991
FSC:8040
NIIN:00N037686
MSDS Number: BQVBP

Responsible Party
PALMER INTERNATIONAL INC
WORCESTER, PA 19490
US

Emergency Phone: 215-584-4241

Info Phone: 215-584-4241

Cage: 00933

Contractor
PALMER INTERNATIONAL, INC.
WORCESTER, PA 19490 US

Telephone: 610-584-4241

Cage: 00933

Ingredients

<0.1

CAS: 25068-38-6

RTECS: KC2100000

Fraction By Weight: 20-25%


EPOXY PHENOL NOVOLAC RESIN; (EPOXY PHENOL NOVOLAC)

CAS: 28064-14-4

Fraction By Weight: <5%


SILANE, 3-(2,3-EPOXYPROPOXY)PROPYLTRIMETHOXY;

CAS: 2530-83-8

RTECS: VV4025000

Fraction By Weight: <1%


COLLOIDAL SILICA

CAS: 67762-90-7

Fraction By Weight: <2%

OSHA PEL 20 MPPCF (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


ZIRCONIUM OXIDE

CAS: 1314-23-4

RTECS: ZH8800000

Fraction By Weight: 70-75%

OSHA PEL 5 MG/M3; 10 STEL

ACGIH TLV: 5 MG/M3; 10 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES: CAN CAUSE IRRITATION.
SKIN: PROLONGED OR REPEATED CONTACT CAN CAUSE MODERATE IRRITATION,
DERMATITIS. INHAL: NORMALLY NO PROBLEM UNLESS HEATED. INGEST:
SLIGHTLY TOXIC.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/LG AMTS OF WATER FOR @ LST 15 MIN, LIFT LIDS
OCCAS; GET PROMPT MED ATTN. SKIN: WASH THORO W/SOAP & WATER, REMOVE
CONTAMD CLTHG PROMPTLY; WASH CLTHG BEFORE REUSE. INGEST: DO NOT
INDUCE VO MIT! KEEP WARM, QUIET & GET MED ATTN. ASPIR OF MATL INTO
LUNGS DUE TO VOMIT CAN CAUSE CHEM PNEUM WHICH CAN BE FATAL. INHAL:
MOVE TO FRESH AIR.IF BRTHG IS DFCLT, ADMINISTER OXYGEN. IF BRTHG
(SUPP DATA)

Fire Fighting

Flash Point:>400F,>204C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG. USE
WATER FOR COOLING MATERIAL STORED IN VICINITY OF FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:SMALL/LARGE SPILL: SCRAPE UP/SOAK UP WITH
ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:IF TLV OF PROD IS EXCEEDED, A NIOSH/MSHA APPRVD
AIR SUPPLY RESP IS ADVISED IN ABSENCE OF PROPER ENVIRONMENTAL CTL.
OSHA REGS ALSO PERMIT OTHER NIOSH/MSHA APPRVD RESP UNDER SPECIFIED
CNDTNS. (SEE YOUR SFTY EQUIP SUPPLIER). (SUPP DATA)
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL &/OR LOCAL EXHAUST)
VENTILATION TO MAINTIAN EXPOSURE BELOW TLV.
Protective Gloves:RESISTANT GLOVES SUCH AS: NITRILE RUBB.
Eye Protection:CHEMICAL SPLASH GOGGLES .
Other Protective Equipment:EYE WASH; SAFETY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: HAS STOPPED, GIVE ARTF RESP. KEEP WARM, QUIET & GET MED
ATTN. RESP PROT: ENGINEERING OR ADMINISTRATIVE CONTROLS SHOULD BE
IMPLEMENTED TO REDUCE EXPOSURE.

Chemical Properties

Boiling Pt:B.P. Text:>392F,>200C
Melt/Freeze Pt:M.P/F.P Text:NO
Vapor Pres:SEE INGRED
Vapor Density:NON VOLAT
Spec Gravity:2.75
Evaporation Rate & Reference:NON VOLATILE
Appearance and Odor:GRAY PASTE
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZERS, ACIDS, AMINES AND BASES.
Stability Condition to Avoid:KEEP AWAY FROM HEAT AND OPEN FLAME.
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE AND DIOXIDE,
VARIOUS HYDROCARBONS, ETC.

Disposal

Waste Disposal Methods:SMALL/LARGE SPILL: INCINERATE OR LANDFILL IN
ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.